Options Tab

Find all Master Settings for each Vienna Instruments PRO instance in this tab.
  1. Pitch range: Click-drag to set the master pitch bend range (as controlled by the Perform tab > Pitch Bend slider).

  2. A4 Master Tune: Click-drag to set the master A4 tuning frequency.

  3. Pan Law:

  • Determines how the signal level in the slot rack mixer is affected by panning. Without compensation, the combined loudness of the left and the right signal will be higher if a channel is panned to the center than if it is panned to one side. Pan Law allows for attenuation of the signal when panned to the center.
  • The optimum value depends on the input source. Default = -3 dB
  1. Matrix CC:
  • Sets Control Change number reserved for matrix switching.
  • Please note that a selected value here will disable usage of selected control change number for other purposes.
  1. Interval Mode: Sets the global interval mode. Polyphonic Legato is selected by default in a new Vienna Instruments PRO instance.

  1. Sync Matrix:
  • ON: Enables synchronization of cell position when switching between Matrices of the same size (they need to contain the same material as well)
  • ON + Ctl: Enables additional synchronization of all matrix controls between matrices.
  1. Sync Mixer:
  • No sync: Mixer only affects the selected cell
  • Sync (green): The slot mixer for all cells in the Vienna Instruments instance is globally synchronized.
  • Sync (orange): The slot mixer for all cells in a matrix is synchronized.)
  1. Master Filter Type:
  • Click to select master filter type.
  • LP6 is a less steep filter than LP12.
  1. Master filter Freq 1:
  • Sets master filter start frequency.
  • Click-drag to change value.
  • Double-click to edit value. Press Enter key to confirm.
  1. Master filter Freq 2:
  • Sets master filter end frequency.
  • Click-drag to change value.
  • Double-click to edit value. Press Enter key to confirm.
  1. Master filter Curve:
  • Click-drag to change value.
  • Double-click to edit value. Press Enter key to confirm.
  1. Filter Curve View: Click-drag anywhere to change filter curve.

  2. Mic Delay Scaler: Only available for Synchron Series ROOM-MIX Presets: Inserts runtime-delay on the ROOM-Mix slots. Default: 100 (equals 18 ms for Synchron Strings ROOM-Mix Presets).

  3. MIDI Dump (also below Matrix List in BASIC View): Click MIDI DUMP and the current Matrix Selection, Cell Position, A/B Position, Sequencer Root Key and Scale Type of the selected Vienna Instruments PRO Interface will be dumped to the record-enabled track in your sequencer as MIDI information.

  4. Sequencer: Switches to Sequencer View

  5. On/off: Enables/Disables Sequencer